[Technology] Analysis of Elevator Door Cover Standards

Vertical elevators can be said to be the portal of each floor, and elevator doors and door covers have also become the focus of elevator room design. However, in actual work, many designers do not understand the structure and specifications of the elevator.

So as a designer, what knowledge should I know the elevator?

[Technology] Analysis of Elevator Door Cover Standards Today we use a certain hotel to electricity. For example, the metal elevator door cover in the staircase , take a look at the above In the case, what knowledge points need to be understood by the designer (PS: analyze according to the number above).

01.

The size of the elevator door

Are there any regulatory requirements?

The specifications of the elevator door are divided into two cases : First, when the architectural design is used as an elevator well, the reserved elevator door hole size; the other is to do it After the interior decoration, the door hole is finally presented.

The size of the original elevator door hole depends on the elevator load standard. The relevant specifications set the number of elevators of architecture, the number of elevators in each elevator, and the corresponding elevator specification size And the elevator door hole size , all are standardized, and the specified quite detailed .

However, as an interior designer, we remember the completion surface width of the following common elevator doors.

[Technology] Analysis of Elevator Door Cover Standards

Common finished surface width of elevator doors ↑

ps: The size is the clear door opening size of the elevator, and the load capacity refers to the weight including the elevator decoration materials.

02.

What is the difference between elevator door covers and ordinary door covers

? p>Let’s first take a look at the differences between the node methods of ordinary door covers and elevator door covers:

[Technology] Analysis of Elevator Door Cover Standards

Normal door cover standard drawing↑

[Technology] Analysis of Elevator Door Cover Standards

Elevator door cover standard picture↑

According to the comparison of the above two pictures, we can see that the elevator door cover is composed of two parts:

Part of it is the steel door cover of the elevator structure itself, which is what I commonly call \”small door cover\”;

Part of it is the decorative door cover made of decorative materials,which is what most of us designers think of Elevator door covers

<img src=\"https://p3-sign.toutiaoimg.com/pgc-image/1c1b8d59306d44e59cf441405e40a55e~tplv-tt-origin-web:gif.jpeg?_iz=58558&fROM = Article.pc_detail & LK3S = 953192F4 & X-EXPIRES = 1738368925 & X-SIGNATURE = lbtzkmeym7zq1trlq7%2b4riy3lho%3d \"/

Yes, the elevator has two door sets. ↑

So, elevator door cover and decoration What is the difference between the door cover?

From the material point of view: The elevator door cover is generally steel frame, and the decorative door cover can be a variety of materials;

From the perspective of location relationship: The ordinary door cover is close to the indoor space, and the elevator door cover is close to the elevator well; .com/PGC-IMAGE/878AEC5199AB4F8BA40C254BEC9818 ~ TPLV-TT-Origi N-WEB: GIF.JPEG? X-EXPIRES = 1738368925 & X-Signature = no2iqmbokj%2FTZ811ugjwrmoutpc%3D \”/>

PS: The use of galvanized iron is blocked in order to avoid exogenous power from the elevator, causing damage to the elevator door cover structure. The aesthetics, while the elevator door sleeve exists to meet the functionality of the staircase door. In order to ensure the beauty of the elevator door cover, we usually use the constructor of the elevator door cover with the decorative door sleeve The door cover is processed;

Therefore, in the completed project, we can\’t see the elevator door cover. In terms of angle, the elevator door cover is mainly drawn by the building unit. The decorative door sleeve is drawn by us. Therefore, when we draw elevator -related nodes, you should check the corresponding civilian drawings. Can you follow the next step?

Please remember that people who have stepped on countless pits pass by ~~~~~

[Technology] Analysis of Elevator Door Cover Standards

Okay, after understanding the content above, let\’s return to the design case of the beginning of the article. I think you should be able to know the node of the door cover very clearly now The practice is as shown in the figure below:

[Technology] Analysis of Elevator Door Cover Standards

03.

Wall surface gum sticky

Or do it?

In fact, in our opinion, whether it is dry or adhesive, it is firm, safe, and reliable for the fixing of wooden jewelry. The fixed method is not too big in itself. The real problem should be under the case? When the area of ​​the wooden surface is not large, and the layer height is not high, and the shape is relatively simple and simple, it is recommended to use conventional silicone glue or structural glue for adhesion;

[Technology] Analysis of Elevator Door Cover Standards

Wooden trim dry hanging scene ↑

In turn, if the use area of ​​wood jewelry is large, and the layer height is higher than that of the layer height than When the shape is relatively complicated, it is recommended to pick it upFix it in the form of dry hanging, which is more stable. not P> What should I know about interior design?

We can understand the elevator car as a \”steel box\” . There are no changes in other structural practices. It\’s just that it is fixed on the concrete grassroots, and in the car, it is fixed on the steel structure, which is nothing more; P>

The area of ​​the ventilation port is required> 1%of the car area, and the minimum scale of the escape port must be guaranteed ≥350mm*500mm.

<img src = \"https://p3-sign.toutiaoimg.com/pgc-image/601eac0d3FDE42BF8BECDE69A817~tplv- origin-JPEG?_iz=585588 & from = article.pc_detail & lk3s = 953192F4 & X-EXPIRES = 1738368925 & X-Signature = NUAHDJXGRSKJ8GKF1N98LOTCWCQ%3D \"/

At the same time, the national standard also stipulates that if the car wall is below 1100mm, a armrest should be set up at a height of 900 ~ 1100mm. Establish and should not be in contact with glass.

At the same time, the front and side of the elevator car should be set up with an elevator handrail of 800 ~ 850mm.

Regarding the content of the elevator car, let\’s talk about it for the time being. Finally, let\’s enjoy a few design cases about elevator door sleeves together. I hope you can analyze these cases through what you have learned today. What is the practice of the door cover.

[Technology] Analysis of Elevator Door Cover Standards